In Doppler ultrasonic flowmeters, ultrasonic energy is transmitted into the pipe. Some of this energy is reflected by particles, bubbles, and eddies in the flow stream. The frequency difference between the transmitted energy and its reflected ultrasonic signal is used to determine the flow in the pipe... click for more
For the past few installments of "Applications Corner," we’ve been considering some unique applications that I’ve run into over the years. Last month we examined instrument selection for below absolute zero pressure. This month we’ll consider how processes that operate at pressures below atmospheric pressure impact flow measurement...
click for more
Most flowmeters are sensitive to the upstream and downstream piping in which they are installed. They are especially sensitive to the upstream piping, so much so that many discussions only focus on the upstream piping, even though both can be important...
click for more
YOUR FEEDBACK
We value your comments and suggestions. Please e-mail us at news@appliedmc.com.
Unless otherwise noted, receipt of your e-mail constitutes permission to include its contents (or parts thereof) in the E-zine.
ABOUT SPITZER AND BOYES, LLC
Spitzer and Boyes, LLC sells Consumer Guides for end-users that contain detailed product information and analysis about Coriolis Mass Flowmeters, Differential Pressure Flow Transmitters, Magnetic Flowmeters, Ultrasonic and Correlation Flowmeters, Vortex Shedding and Fluidic Flowmeters, Non-Contact Level Gauges and other Instrumentation. They also offer seminars on these topics at various locations across the United States.
|

This email was sent to you from
Applied Measurement & Control,
New York State’s Leading Provider of Instrumentation and Process Controls.
For more information please visit our website at www.appliedmc.com
call us at 1-585-924-3281 or send us an email at sales@appliedmc.com
|